Skip to content
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- This Shrinkage Bar Mould-Two Gang is used for determination of soundness. The change in length of the specimen is determined by Length Comparator listed in the concrete section
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- The Sieve Shaker Motorised can carry up to eight sieves of 20cm diameter. It is driven by a ¼ HP geared motor. The table is inclined from the vertical axis and the direction of inclination changes progressively in a clockwise direction.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Used for grain size analysis of soils where more than 10% of the material will pass through 75 microns B.S. sieve. Manufactured from clear transparent glass having uniform clarity throughout the upper end on which density scale is engraved
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- These kits are utilized profitably for soil richness assessment and compost suggestion. At our creation lab, propelled innovation is consolidated with unrivaled evaluation crude material, so as to convey a faultless extent at our customer's end.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- The apparatus consists one each of compaction mould steel, 100 mm I.D. x 127.3mm height x 1000 cc.volume, complete with collar and base plate. Compaction Rammer is 2.6 kgs in weight x 310mm controlled fall.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- It is a super-conducting device and involves the transfer of heat by boiling and condensation of fluid and hence the transfer of heat takes place under nearly isothermal condition.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- For reaching greater depths and to facilitate easy and constant rate of penetration 1 to 2.5cm/sec of the cone this engine-driven Static Cone Penetrometer of 100 KN (10,000 Kgf) capacity is preferable.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Swell Pressure developed by soil specimens moulded to desired densities at known moisture contents when soaked in water. The load applied to restrain the Swelling is Transferred on to a load measuring proving ring through a perforated swell plate and a load transfer bar.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- The cell is useful for testing 38mm dia x 76mm high soil specimen. Transparent Perspex chamber with anvil and loading plunger, the cell is easily opened by releasing four nuts of the tie rods.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Determination of soil shear strength is essential for designing the foundation of structures, soil and soil retaining structures, soil slopes, etc., Shear strength of soil depends on various factors and in situ soil conditions.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Vane Shear Apparatus (Field Type) is designed for conducting in situ vane shear test from bottom of a borehole in saturated cohesive deposits for determining their in place shearing resistance.
- Read more
-