Skip to content
-
-
- Asphalt Testing Lab, Civil Engineering
-
Rated 0 out of 5
- The Rolling Thin-Film Oven Test (RTFOT) is one of the most commonly used standardized tests to simulate the STA of binders. This test is used to measure the combined effects of heat and air on a thin film of bitumen or bituminous binder in permanent renewal.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- With prosperous industry practice, we are known to offer Sand Replacement Apparatus. It is made by experts using advanced technology. The Sand Replacement apparatus is used for the determination of the degree of compaction on site
- Read more
-
-
- Asphalt Testing Lab, Civil Engineering
-
Rated 0 out of 5
- For the empirical measurement of Saybolt Viscosity of petroleum products at specified temperatures between 70°F and 210°F. This is also used for determining the Say bolt Furol viscosity of bituminous materials at temperatures of 250, 275, 300, 350, 400 and 450°F.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Semi Automatic Cone Penetrometer is soil testing lab equipment that is used to identify the moisture content in which the clay soil transfers into a liquid state from the normal solid state.
- Read more
-
-
- Asphalt Testing Lab, Civil Engineering
-
Rated 0 out of 5
- The Semi-Automatic Penetrometer for Liquid Limit consists of a cast iron base with coarse and fine leveling screws, a digital penetration measurement gauge 0.01 mm resolution/readability and an automatic penetration timer unit.
- Read more
-
-
- Civil Engineering, Heat and Mass Transfer Testing
-
Rated 0 out of 5
- Shell and Tube Heat Exchanger are popular in process industries because they occupy less space and offer reasonable temperature drop. The apparatus consists of fabricated shell, inside which tubes with baffles on outer side are fitted. The present set up is a 1-2 heat exchangers, with cold water flows through shell.
- Read more
-
-
- Cement Testing Lab, Civil Engineering
-
Rated 0 out of 5
- The mould, which has 25mm x 25mm x 250 mm effective gauge length is made of mild steel and has accurately machined faces. The parts of the moulds are tight-fitting and firmly held together when assembled.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- Shrinkage limit is the maximum water content at which a reduction in water content does not cause an appreciable reduction in the volume of the Soil Mass.
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- This Shrinkage Bar Mould-Two Gang is used for determination of soundness. The change in length of the specimen is determined by Length Comparator listed in the concrete section
- Read more
-
-
- Civil Engineering, Soil Testing Lab
-
Rated 0 out of 5
- The Sieve Shaker Motorised can carry up to eight sieves of 20cm diameter. It is driven by a ¼ HP geared motor. The table is inclined from the vertical axis and the direction of inclination changes progressively in a clockwise direction.
- Read more
-
-
- Asphalt Testing Lab, Civil Engineering
-
Rated 0 out of 5
- For casting of cement briquettes for tensile strength tests. It is a two part split mould made of gun metal. Two thumb screws facilitate easy and quick assembling and dismantling of the mould.
- Read more
-
-
- Civil Engineering, Heat and Mass Transfer Testing
-
Rated 0 out of 5
- Long Tube Single Effect Evaporator Are Usually Used For The Concentration Of Foamy Liquids. Evaporation Deals With The Concentration Of A Non-Volatile Solute From A Solution By The Removal Of Required Amount Of Volatile Solvent. Usually, The Solvent Is Water.
- Read more